- Auto Ranging
- 2000 count
- 0.5% DCV accuracy
- DC voltage to 1000V
- AC voltage to 750V
- AC/DC current to 10A
- Resistance to 43M ohm
- Continuity
- Diode test
- Protective rubber boot included
Specifications | model 2708 | DC Volts | | Ranges | 430mV, 4.3V, 43V, 1000V | Resolution | 100uV, 1mV, 10mV, 100mV, 1V | Accuracy | +-(0.5% + 1 Digit) | Overload Protection | 200 mV Range 500V DC + AC Peak, 350V RMS Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine | Input Impedance | 10 M | AC Volts | | Ranges | 430mV, 4.3V, 43V, 430V, 750V | Resolution | 100 uV, 1 mV, 10 mV, 100 mV, 1V | Basic Accuracy | +-(1.5% + 4 Digits) | Frequency Response | 50 to 100 Hz | Overload Protection | 200 mV Range: 500 VDC + AC Peak, 350V RMS, Sine: All Other Ranges: 1200 V DC + AC Peak, 800V RMS, Sine: | Input Impedance | 10 M | DC Current | | Ranges | 430uA, 43mA, 430mA, 10A | Resolution | 0.1uA, 10uA, 100uA, 10mA | Accuracy | +-(0.5% + 1 Digit) | Burden Voltage | 10A and 200mA range: 750mV max.; All Other Ranges: 325mV max. | Overload Protection | 10A Range: Unfused: All Other Ranges: 250V Fuse | AC Current | | Ranges | 430uA, 43mA, 430mA, 10A | Resolution | 0.1uA, 10uA, 100uA, 10mA | Accuracy | +-(1.2% + 4 digits): 10A Range: +-(2% + 4 Digits) | Frequency Response | 50 to 500 Hz | Burden Voltage | 10A and 200mA Range: 750mV max.: All Other Ranges: 325mV max. | Overload Protection | 10A Range: Unfused; All Other Ranges: 250V Fuse | Resistance | | Ranges | 430, 4.3kOhm, 43kOhm, 4.3MOhm, 43MOhm | Resolution | 0.1, 1 Ohm, 10Ohm, 100Ohm, 1 kOhm, 10 kOhm | Basic Accuracy | 430 Range: +-(0.3% + 3 Digit) | | 4.3k - 4.3M Range: +-(0.3% + 2 dgt) | Overload Protection | 500 VDC + AC Peak | Diode Test | Tested at 1.6mA and 3.2V Max. | Transistor Test (hFE) | Does not apply | Capacitance | | Ranges | Does not apply | Resolution | | Accuracy | | Test Frequency, Voltage | | Frequency | | Ranges | Does not apply | Resolution | | Accuracy | | Sensitivity | | Overload Protection | | Logic Probe (TTL) | | Logic Threshold | 1 = 2.8 +- 0.8V, 0 = 0.8 +- 0.5V | Minimum Pulse Width | 25 nS | Input Impedance | 120 k nom. | Overload Protection | 500 VDC + AC Peak | Temperature | | Range | Does not apply | Accuracy | | -4 0 to + 900 0 F (-20 0 to 500 0 C) | | 900 0 to + 1400 0 F (500 0 to + 750 0 C) | | Continuity Tone | Tone Sounds within 100 mS for Resistance Under 100V | General | | Display | 3 1/2 digit, high-contrast 0.7'' LCD, 1999 counts | Sampling | 3 times/sec. (nominal) | Operating Temp: | 32 0 to 104 0 F (0 0 to + 40 0 C), 0 to 70% RH | Storage Temp | -4 0 to 140 0 F (-20 0 to 60 0 C), 0 to 80% RH | Power Requirements | 9V NEDA 1604. | Battery Life | 200 hours (alkaline) nominal 275 hours (alkaline) Nominal (2703B only) | Dimensions (HxWxD) | 5.9x3.1x1.3'' (150x79x33 mm) | One Year Warranty | Accessories | SUPPLIED: Battery, Test Leads, Instruction Manual, Thermocouple Probe (2706A only) OPTIONAL: TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A), PR-28A High Voltage DMM Probe (40kVDC), TL-130A General Purpose DMM Kit Carrying Case (not included): LC-29B |
|
|
|
¹è¼ÛÁö¿ª : Àü±¹
¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
[¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]
¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)
|
|
|
|
|