Ȩ | ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | ¹è¼ÛÁ¶È¸
     
    
Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ
½ºÄÚÇÁLCR/ÀÓÇÇ´ø½º¸ÖƼ¸ÞÅÍŬ·¥ÇÁ¸ÞŸÁÖÆļöÄ«¿îÅÍÆã¼Ç¹ß»ý±âÀý¿¬/Á¢ÁöÀúÇ×±âÇϳ׽ºÅ×½ºÅͺÎÇ°Å×½ºÅÍÁ¦Á¶Ç°¸ñ/¹ýÁ¤ÀåºñĶ¸®ºê·¹ÀÌÅÍ´©¼³Àü·ù°è·ÎÁ÷ºÐ¼®±âÇ÷°½º¸ÞŸ¼­ÁöÅ×½ºÅÍÆ®·£½ºÅ×½ºÅÍÆÄ¿ö¸ÞŸ°Ë»ó±â¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°(1)¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°(2)ATTEN // KORAD¿¡³ÊÁöÁø´ÜÀåºñÈ©ÅØÄÚ¸®¾Æ/hopetech koreaOWONFLUKEÃÑÆÇÀúÇ×°¡°¨±âÂ÷´Ü±âÅ×½ºÅÍHIOKIƯÆÇÇѱ¹»êDMM6ŸÁ¡±â·Ï°èLUTRON(·çÆ®·Ð)YOKOKAWA Àåºñ(ÃÑÆÇÃë±ÞÀåºñ)Àü¾Ð/Àü·ù probeGWINSTEK(±»ÀªÆ¯ÆÇÀåºñ)CCTVÅ×½ºÅͱâÁ¢Áö¿¬¼Ó¼º½ÃÇè±âscopeÇÁ·ÎºêÀÚµ¿Àü¾ÐÁ¶Á¤±âÀÓÇÇ´ø½º¸ÞÅÍ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñAPPLENTµðÁöÅÐ ´Ù±â´É°èÃø±â¹Ì²ô·³¹æÁö,µµ¸·Çü¹Ù´ÚÀç¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°/Á÷Á¢»ý»ê(3)

8030U
°¡°Ý¹®ÀÇ

GFC-8270H
°¡°Ý¹®ÀÇ

   Home > Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ > ÁÖÆļöÄ«¿îÅÍ > << 3GHz
 
MODEL : GFC-8270H   
ÁÖÆļöÄ«¿îÅÍ(2.7GHz)
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 4ÁÖÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

ºñÆ®¸¶Æ®¸¦ ã¾ÆÁּż­ °¨»çÇÕ´Ï´Ù. ÁÁÀº ÇÏ·ç µÇ¼¼¿ä!
 
   

¡á

Frequency, Period measurement

¡á

Microprocessor controlled intelligent counter

¡á

High resolution at both high and low frequency

¡á

0.01Hz ~ 2.7GHz frequency range

¡á

10mVrms High sensitivity

¡á

100nHz resolution for 1Hz

¡á

Self diagnosis routine

¡á

Variable Trigger Level control

¡á

Display hold function

SPECIFICATIONS
Display8 digits with Hz, kHz, MHz, GHz, S, mS, µS, nS and overflow
Gate TimeContinuously vary from 10mS to 10S, or 1 period of input depending on whichever is greater
Accuracy+(Resolution +Timebase error)
Channel A
RangeDC coupled 0.01Hz ~ 120MHz£»AC coupled 30Hz ~ 120MHz
Sensitivity10mVrms typical£» 50mVrms max
CouplingAC or DC switchable
FilterLow pass, switchable in or out for channel A.-3dB point of nominally 100kHz
Impedance1M¥Ø//40pF
Attenuatorx 20dB
Trigger Level Adjustment-2.5 VDC to +2.5 VDC
ResolutionThe maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively.
At least 7,6,5 digits are display for 1S, 100mS, 10mS gate time respectively
Period Range8nS to 100S at least 7 digits displayed for per second of gate time
Channel B
Range50MHz to 2.7GHz
Sensitivity<50mVrms (10mVrms typical)
CouplingAC only
Time Base
Aging Rate1 ppm, per Month
Temperature5 ppm 23¡ÆC + 5¡ÆC
Line Variation+0.005 ppm for +10% variation
Power SourceAC 100V/120V/220V/240V ¡¾10%, 50/60Hz
AccessoriesInstruction manual ¡¿ 1,
Power cord ¡¿ 1,

GTL-101
¡¿ 1
Dimensions & Weight230(W) ¡¿ 95(H) ¡¿ 280(D) mm, Approx. 2.2kg

¹è¼ÛÁö¿ª : Àü±¹

¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)