Ȩ | ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | ¹è¼ÛÁ¶È¸
     
    
Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ
½ºÄÚÇÁLCR/ÀÓÇÇ´ø½º¸ÖƼ¸ÞÅÍŬ·¥ÇÁ¸ÞŸÁÖÆļöÄ«¿îÅÍÆã¼Ç¹ß»ý±âÀý¿¬/Á¢ÁöÀúÇ×±âÇϳ׽ºÅ×½ºÅͺÎÇ°Å×½ºÅÍÁ¦Á¶Ç°¸ñ/¹ýÁ¤ÀåºñĶ¸®ºê·¹ÀÌÅÍ´©¼³Àü·ù°è·ÎÁ÷ºÐ¼®±âÇ÷°½º¸ÞŸ¼­ÁöÅ×½ºÅÍÆ®·£½ºÅ×½ºÅÍÆÄ¿ö¸ÞŸ°Ë»ó±â¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°(1)¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°(2)ATTEN // KORAD¿¡³ÊÁöÁø´ÜÀåºñÈ©ÅØÄÚ¸®¾Æ/hopetech koreaOWONFLUKEÃÑÆÇÀúÇ×°¡°¨±âÂ÷´Ü±âÅ×½ºÅÍHIOKIƯÆÇÇѱ¹»êDMM6ŸÁ¡±â·Ï°èLUTRON(·çÆ®·Ð)YOKOKAWA Àåºñ(ÃÑÆÇÃë±ÞÀåºñ)Àü¾Ð/Àü·ù probeGWINSTEK(±»ÀªÆ¯ÆÇÀåºñ)CCTVÅ×½ºÅͱâÁ¢Áö¿¬¼Ó¼º½ÃÇè±âscopeÇÁ·ÎºêÀÚµ¿Àü¾ÐÁ¶Á¤±âÀÓÇÇ´ø½º¸ÞÅÍ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñAPPLENTµðÁöÅÐ ´Ù±â´É°èÃø±â¹Ì²ô·³¹æÁö,µµ¸·Çü¹Ù´ÚÀç¹ýÁ¤/Çü½Ä½ÂÀÎÁ¦Ç°/Á÷Á¢»ý»ê(3)

4263B
°¡°Ý¹®ÀÇ

886
°¡°Ý¹®ÀÇ

PM 6304
°¡°Ý¹®ÀÇ

LCR-829
°¡°Ý¹®ÀÇ

LCR-819
°¡°Ý¹®ÀÇ

   Home > Àü±âÀüÀÚ°èÃø±â/¹ýÁ¤Àåºñ > LCR/ÀÓÇÇ´ø½º > << 100KHz
 
MODEL : PM 6304   
RCL ¸ÞŸ (°í¼º´ÉLCR ¸ÞŸ) (100KHz)
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 4ÁÖÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

FlukeÀÇ Á¦Ç°°¡°ÝÀº ÀüÈ­¹®ÀǸ¸ °¡´ÉÇÕ´Ï´Ù.
 
   

¡á

ÁÖÆļö ¹üÀ§ 50Hz to 100 kHz

¡á

ÀÓÇÇ´ø½º/ÀúÇ×(Z ,R) 0.0000 Ohm to 200 MOhm

¡á

Äܵ§¼­(C) 0.0 pF to 31.8mF

¡á

ÀδöÅϽº(L-ÄÚÀÏ) 0.0 uH to 637 kH

¡á

DC Å×½ºÆ® ¸ðµå 300 mV , 1V , 2V

¡á

Q 0.002 to 1000

¡á

D 0.002 to 1000

¡á

Á¤È®µµ 0.1% (PM6304C ´Â 0.05%)

¡á

DC ¹ÙÀ̾(³»ºÎ) 2 V

¡á

DC ¹ÙÀ̾(¿ÜºÎ) 0 to 40 V

¡á

Bin ÇÁ·Î±×·¥ IEEE488 , RS-232

¡á

¸®¸ðÆ® Bin ÇÁ·Î±×·¥ PM 9559B

Spec ¹× Ư ¼º

AC Test Mode
Test frequency PM 6306: 50, 60, 100, 120 Hz
200 Hz to 100 kHz (100 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
PM 6304: 50, 60, 100, 120 Hz
200 Hz to 20 kHz (100 Hz steps)
100 kHz
Test frequency accuracy PM 6306: 0.01%
PM 6304: 0.01%
Test signal levels PM 6306: 50 mV to 2V (10 mV steps) via 100W
PM 6304: 50 mV via 100W
1V via 100W
2V via 400W
Basic measurement accuracy at normal measurement mode PM 6306: 0.1% ¡¾ 1 digit (for ©ø 0.25V, £ 50 kHz)
0.1% * (f/50 kHz) ¡¾ 1 digit (for ©ø 0.25V, > 50 kHz)
0.1% * (0.25V/Vt) ¡¾ 1 digit (for < 0.25V, £ 50 kHz)
PM 6304: 0.05% ¡¾ 1 digit (for PM 6304C, £ 2 kHz)
0.1% ¡¾ 1 digit (for £ 20 kHz)
0.4% ¡¾ 1 digit (100 kHz)
0.5% ¡¾ 1 digit (for 50 mV £ 20 kHz)
2.0% ¡¾ 1 digit (for 50 mV, 100 kHz)
DC bias
Internal PM 6306: 0 to 10V (0.1V steps)
PM 6304: 2V
External PM 6306: 0 to 40V
PM 6304: 0 to 40V
DC test mode (Optional)
Test signal levels PM 6306: 50 mV to 2V (10 mV steps) via 100W
PM 6304: 300 mV via 100W
1V via 100W
2V via 400W
Basic measurement accuracy PM 6306: 0.1% ¡¾ 1 digit (for ©ø 0.25V)
PM 6304: 0.1% ¡¾ 1 digit (for 1V)
Contact check (PM 6306 only)
Pass PM 6306: 3W
Fail PM 6306: 3W (with indication of failed connection lead)
Maximum measuring ranges
Impedance/Resistance AC Z or RAC 0.0000W to 200 MW
Resistance DC RDC 0.0000W to 50 MW
Capacitance C 0.00 pF to 31.8F
Inductance L 0.00 mH to 637 kH
Quality factor Q 0.000 to 1000
Dissipation factor D 0.000 to 1000
Phase Angle F -179 to + 180 deg
Voltage monitor VX 0.1 mV to 2.00V
Current monitor IX 0.005 mA to 10.0 mA
Maximum resolution
Impedance/Resistance AC Z or RAC 0.1 mW
Resistance DC RDC 0.1 mW
Capacitance C 0.01 pF
Inductance L 0.01 mH
Quality factor Q 0.001
Dissipation factor D 0.001
Phase angle F 0.1 deg
Voltage monitor VX 0.1 mV
Current monitor IX 0.001 mA
Circuit diagram
Display 1 of 7 different equivalent circuit diagrams
Auto Mode
Read-out Dominant and secondary parameter
Equivalent circuit diagram Parallel for R+C, Serial for R+L
Manual mode
Read-out Dominant and secondary parameter or Z, F, D, Q, VX, IX
Equivalent circuit diagram Parallel or serial selectable
Average function
Function Exponential averaging in continuous mode
Levels PM 6306: 3 (and off)
PM 6304: 1 (and off)
Deviation mode (PM 6306 only)
Relative range in respect to reference value PM 6306: -100% to +100%
Measuring modes (Normal)
Continuous 2 measurements/s
Single Triggered via "TRIG" key
Triggered via handler interface
Triggered via IEEE-488 or RS-232
Test frequency PM 6306: 50, 60, 100, 120 Hz
200 Hz to 100 kHz (100 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
DC (optional)
PM 6304: 50, 60, 100, 120 Hz
200 Hz to 20 kHz (100 Hz steps)
100 kHz
DC (optional)
Read-out Display or via IEEE-488 or RS-232 interface
Measuring Modes (Fast)
Max. speed 10 measurements/s
Test frequency PM 6306: 200 Hz to 100 kHz (200 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
DC (optional)
PM 6304: 200 Hz to 20 kHz (200 Hz steps)
100 kHz
DC (optional)
Single Triggered via handler interface
Triggered via IEEE-488 or RS-232
Read-out Via IEEE or
Measuring Modes (Fast)
Max. speed 10 measurements/s
Test frequency PM 6306: 200 Hz to 100 kHz (200 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
DC (optional)
PM 6304: 200 Hz to 20 kHz (200 Hz steps)
100 kHz
DC (optional)
Single Triggered via handler interface
Triggered via IEEE-488 or RS-232
Read-out Via IEEE or RS-232 interface (display blanked)
Binning
Standard bins 9
Special bins Bin "0" and bin "fail"
Bin programming via IEEE-488 interface
RS-232 interface
Bin programmer (PM 6304 only)
Bin limit programming Absolute or relative
Trim function
Open circuit Open circuit compensation Z > 100 kW
Short circuit Short circuit compensation Z < 10W
Protection against charged capacitors
C < 2 mF PM 6306: Vmax < 200V
PM 6304: Vmax < 500V
2 mF o C o 2 mF PM 6306:
V
max < 47 x (C/mF) -0.234
(Vmax in V, C in mF)
PM 6304: Vmax. < 117 x (C/mF) -0.234
(Vmax in V, C in mF)
Stored settings (non-volatile memory)
Front panel settings 9 + 1 (trim figures included)
Bin settings 9 + 1
Print measurements results
Print measurements results Via RS-232 interface for serial printers
Calibration interval
Calibration interval 1 year
Environmental Conditions
Operating temperature 0¡Æ to 50¡Æ C
Storage temperature -40¡Æ C to 70¡Æ C
Power requirements 100/120/220/240V + 10%
Line frequency 50/60 Hz
Power Consumption PM 6306: 44 VA
PM 6304: 31 VA
Safety According to CE-regulation 73/23 EN61010-1 CAT II, Pollution Degree 2
EMC According to CE regulation 89/336:
Emission according to EN 55011, Group 1 Class B, respectively CISPR 11.
Immunity according to EN 50082-1, inclusive IEC 801-2, -3, -4
Warm-up time PM 6306: 30 minutes
PM 6304: 5 minutes
Dimensions and weight
W x H x D 315 x 105 x 405 mm (12.4 in x 4.13 in x 15.9 in)
Weight PM 6306: 5.3 kg (11.7 lb)
PM 6304: 4.7 kg (10.4 lb)

¹è¼ÛÁö¿ª : Àü±¹

¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
     ¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
     [¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼­)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]

¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)