¡á |
Identifies port services like Ethernet, ISDN, POTS and Token-Ring while
reporting such crucial information
|
|
as network speed, capability and location of
switches and other network devices.
|
¡á |
Pinging function verifies connectivity to network devices and queries
PC/NIC's.
|
¡á |
Detects legacy "Phantom Power", reports current and voltage capability of
analog telephone lines,
|
|
identifies (maps) remotes while cable testing
|
¡á |
Conducts link tests to ID speed
|
¡á |
Verifies functional speed capability of terminated unconnected cable runs by
sampling data packets
|
|
between two LanScaper units, which exercises the run and
reports the result
|
¡á |
Automatically accesses DHCP host and obtains network information
|
¡á |
Tests cabling configuration and verifies connectivity and length of run
while conducting tests for opens,
|
|
shorts, miswires, split pairs, and reversals
|
|
Identifies HUBs, NIC, or auto MDI/MDI-X devices
|
|
Blinks HUBs to ascertain connected configuration
|
¡á |
Displays advertised network speed/duplex
|
|
Measures and reports any voltage on lines
|
¡á |
Wiremaps network connections with remote identifiers
|
¡á |
Generates multiple tone levels for signal tracing and cable identification
|
|
|
Description |
|
The new LanScaper¢â Network Tester is the first in a new line of Physical Layer
Network |
|
Management Devices. The LanScaper¢â combines the functions of a high-end
cable tester and |
|
length measurement device with the capability to monitor and
correct network problems connected |
|
with the physical layer and link conditions
of the network. |
Physical Dimensions |
Size: |
15 x 7.4 x 3.2 cm(5.9 x 2.9 x 1.25 inches) |
Weight: |
200 grams (7 oz.) With battery |
Environmental |
Operating temperature: |
0 to 50ºC (32 to 122ºF) |
Storage temperature: |
-30 to 80ºC (-20 to 176ºF) |
Humidity: |
10% to 90%, non-condensing |
Battery Life |
(9V Alkaline battery, typical) times
are for the full capacity of the battery used continuously in one of the
following modes: |
Standby: |
2.5 years |
Cable Testing: |
50 hours, no backlight 27 hours, 50%backlight
|
Network Testing: |
15 hours, no backlight 14 hours, 50%backlight
|
Cable Types |
shielded or unshielded, Cat5E, Cat5,
Cat4, Cat3 and coax |
Minimum cable length for testing for split
pairs |
1 meter (3 feet) |
Minimum cable length for single-ended cable
test |
1.25 meter (4 feet) |
Length measurement range (CAT
5/6) |
0 to 457 meters (0 to 1500 feet) |
|
|
|
¹è¼ÛÁö¿ª : Àü±¹
¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
[¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]
¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)
|
|
|
|
|