Ȩ | ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | ¹è¼ÛÁ¶È¸
     
    
Àü¿ø°ø±Þ±â/Àü·ÂºÐ¼®±â
Àü¿ø°ø±Þ±â(¹ü¿ë)ÀüÀڷεå(Electric load)AC-DC ÄÁ¹öÅÍAC Power SupplyUPS kikusuiMegger3»óÀü·ÂºÐ¼®±âLaboratory Power AmplifiersÁÖÆļöº¯È¯±â3»óȸ·Î½ÃÇè±â°í¾Ð³»Àü¾Ð½ÃÇè±âÀý¿¬À¯ ³»¾Ð½ÃÇè±â(50kV/60kV)ÆÄ¿ö¸ÞŸ(Àü·Â°è)°í¾ÐÇÁ·Îºê

6813B
°¡°Ý¹®ÀÇ

6812B
°¡°Ý¹®ÀÇ

6811B
°¡°Ý¹®ÀÇ

APS-9501
°¡°Ý¹®ÀÇ

APS-9301
°¡°Ý¹®ÀÇ

APS-9102
°¡°Ý¹®ÀÇ

   Home > Àü¿ø°ø±Þ±â/Àü·ÂºÐ¼®±â > AC Power Supply > GOODWILL
 
MODEL : APS-9301   
ACÆÄ¿ö¼Ò½º (300VA)
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 4ÁÖÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

ºñÆ®¸¶Æ®¸¦ ã¾ÆÁּż­ °¨»çÇÕ´Ï´Ù. ÁÁÀº ÇÏ·ç µÇ¼¼¿ä!
 
   

¡á

True RMS Meter

¡á

ÃÖ´ëÃâ·Â¿ë·® : 1KVA

¡á

Ãâ·ÂÁÖÆļö¹üÀ§ : 45-500Hz

¡á

Ãâ·Â Àü¾Ð : 0-300V

¡á

Ãâ·ÂÀü·ù :8.4A/4.2A(Max/Min)

¡á

4°¡Áö ¸ðµå Save/Recall ±â´É

¡á

Display type : 3 1/2 digit x3

SPECIFICATIONS

Type

APS-9301

APS-9501

APS-9102

Output Capacity

300VA

500VA

1000VA

Output Voltage

0.0 ~ 300.0VAC, 0.1V/step (110V/220V selectable)

Output Current

0~150V, 2.6Arms
0~300V 1.3Arms

0~150V, 4.2Arms
0~300V 2.1Arms

0~150V, 8.4Arms
0~300V 4.2Arms

Frequency

45.0~500.0Hz (50Hz/60Hz selectable)
0.1Hz/step (45.0Hz~100.0Hz), 1Hz/step (100.0Hz~500.0HZ)

Waveform

Sine wave, < 0.5% TDH (Resistance Load)

Line Voltage Regulation

< 0.1%

Load Regulation

+ 0.5% + 0.1V

Save / Recall

4 settings, Save/Recall operated by hand

Protection

Short-Circuit protection, Panel-lock
Over-High Temperature protection, Current Overflow

Measurement

Frequency Counter

Range: 0.0~999.9Hz ; Resolution: 0.1Hz ; Accuracy: + 0.1Hz

RMS Volt-Meter

Range: 0.0~380.0V ; Resolution: 0.1V ; Accuracy: + (1%rdg + 0.1V)

RMS Amp-Meter

Range: 0.000~2.000A ; Resolution: 1.0mA ; Accuracy: + (1%rdg + 5mA)
Range: 1.80~35.00A ; Resolution: 0.01mA ; Accuracy:
+ (1%rdg + 20mA)

Wattage Meter

Range: 0.0~360.0W ; Resolution: 0.1W; Accuracy: + (1.5%rdg + 0.5W)
Range: 320.0~3500.0W ; Resolution: 1.0W; Accuracy:
+ (1.5%rdg + 1W)

Power Factor Meter

Range: 0.000~1.000 ; Resolution: 0.001; Accuracy: + (2%rdg + 0.002)

Power Source

AC 115V/230V+15%, 47 ~ 63Hz, Single phase

Operation Temperature / Humidity

0¡ÆC ~ +10¡ÆC ; <80% (non-concreting)

Dimension

430(W) x 137(H) x 500(D) mm

430(W) x 225(H) x 500(D) mm

Weight

Approx. 20kg

Approx. 25kg

Approx. 35kg


¹è¼ÛÁö¿ª : Àü±¹

¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
     ¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
     [¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼­)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]

¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)