Ȩ | ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | ¹è¼ÛÁ¶È¸
     
    
Àü¿ø°ø±Þ±â/Àü·ÂºÐ¼®±â
Àü¿ø°ø±Þ±â(¹ü¿ë)ÀüÀڷεå(Electric load)AC-DC ÄÁ¹öÅÍAC Power SupplyUPS kikusuiMegger3»óÀü·ÂºÐ¼®±âLaboratory Power AmplifiersÁÖÆļöº¯È¯±â3»óȸ·Î½ÃÇè±â°í¾Ð³»Àü¾Ð½ÃÇè±âÀý¿¬À¯ ³»¾Ð½ÃÇè±â(50kV/60kV)ÆÄ¿ö¸ÞŸ(Àü·Â°è)°í¾ÐÇÁ·Îºê

[HIOKI 3390] Power Analyzer
°¡°Ý¹®ÀÇ

HPM-300
385,000¿ø

HPM-100A ¿ÍÆ®¸Ç Àü·Â°è
°¡°Ý¹®ÀÇ

ITECH IT9121 Digital Power Analyzer
4,120,000¿ø

AC power meter DW3545
°¡°Ý¹®ÀÇ

ÆÄ¿ö¸ÞŸ DW3570
°¡°Ý¹®ÀÇ

   Home > Àü¿ø°ø±Þ±â/Àü·ÂºÐ¼®±â > ÆÄ¿ö¸ÞŸ(Àü·Â°è) > ÆÄ¿ö¸ÞŸ(POWER ANALYZER)
 
MODEL : [HIOKI 3390] Power Analyzer   
[HIOKI 3390] Power Analyzer
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 3ÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

ºñÆ®¸¶Æ®¸¦ ã¾ÆÁּż­ °¨»çÇÕ´Ï´Ù. ÁÁÀº ÇÏ·ç µÇ¼¼¿ä!
 
   

• ±âº» Á¤È®µµ : ¡¾0.05%rdg. ¡¾0.05%f.s.(50/60Hz) ¡¾1.5%rdg. ¡¾0.5%f.s.(100kHz½Ã) • ´ë¿ª : DC 0.5Hz~150kHz • ÀÔ·Â : Àý¿¬4ä³ÎÀÔ·Â(´Ü»ó¿¡¼­ 3»ó4¼±±îÁö ÃøÁ¤¶óÀο¡ ´ëÀÀ) • ÃøÁ¤Ç׸ñ : Àü¾Ð,Àü·ù,À¯È¿Àü·Â,ÇÇ»óÀü·Â,¹«È¿Àü·Â,¿ª·ü,À§»ó°¢,ÁÖÆļö,È¿À²,Àü·ùÀû»ê,Àü·ÂÀû»ê, • Àü¾ÐÇÇÅ©,Àü·ùÇÇÅ©,½ÇÈ¿Ä¡,ÇÔÀ¯À²,À§»ó°¢,À§»óÂ÷,¿Ö°î·ü,ºÒÆòÇü·ü • ÃøÁ¤±â´É : ³ëÀÌÁîÃøÁ¤,Á¤·ù¹æ½Ä¼±ÅÃ,½ºÄÉÀϸµ,¿¡¹ö¸®Áö,È¿À²,¼Õ½Ç¿¬»ê,Âü½ÇÈ¿Ä¡,Æò±ÕÄ¡, • ±³·ù¼ººÐ,Á÷·ù¼ººÐ,±âº»ÆļººÐÀ» µ¿½ÃÃøÁ¤ • µ¥ÀÌÅÍ°»½ÅºñÀ² : 50ms • ¸Þ¸ð¸® : USB¸Þ¸ð¸®,CFÄ«µå»ç¿ë°¡´É(´ë¿ë·®¹Ìµð¾î·Î Àå±âµ¥ÀÌÅÍ ÀúÀå°¡´É) • Åë½ÅÀÎÅÍÆäÀ̽º : USB,LAN(HTTP ¼­¹ö±â´É¿¡ µû¶ó À¥ºê¶ó¿ìÀú¿¡¼­ ¿ø°ÝÁ¶ÀÛ°¡´É) • µ¿±âÃøÁ¤ : °¡´É(ºÎ¼Ó¼ÒÇÁÆ®¿þ¾î¿¡¼­´Â ÃÖ´ë 4´ë¿¡¼­ °£´ÜÇÏ°Ô PC·Î µ¥ÀÌÅ͸¦ ÃëµæÇÏ¿© ±â·Ï°¡´É) • ¿ÂµµÃøÁ¤ : ¹æ»ç¿Âµµ°è¿Í Á¶ÇÕÇÏ¿© ±â·Ï°¡´É(RS-232CÀÎÅÍÆäÀ̽º¿¡ Á¢¼Ó) • °á¼±È®ÀÎ : º¤ÅÍÇ¥½Ã(°£´ÜÇÏ°Ô 3»óÃøÁ¤½ÃÀÇ °á¼±¹Ì½º¸¦ »çÀüÈ®Àΰ¡´É) • Ç¥½Ã : 9ÀÎÄ¡¿ÍÀ̵åÈ­¸é(800µµÆ® X 480µµÆ®) Basic specifications Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, threephase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel Measurement items Voltage, Current, Voltage/current waveform peak, Active power, Reactive power, Apparent power, Power factor, Phase angle, Frequency, Current integration, Power integration, Efficiency, Loss, Voltage/current ripple factor Noise measurement (FFT processing): RMS spectrum of voltage/current Harmonic measurement: RMS value, Content factor, Phase angle, Total distortion, Disequilibrium factor Additional functions (With optional 9791 or 9793 installed in the main unit) : Torque, Rotation, Frequency, Slip, or Motor output Harmonic measurement Input: 4ch, Synchronization frequency range: 0.5Hz to 5kHz, Number of harmonic orders: Max. 100th order Noise measurement Number of channels: 1ch (select one channel from CH1 to CH4), Maximum analysis frequency: 100k/ 50k/ 20k/ 10k/ 5k/ 2kHz Measurement range Voltage range: 15 to 1500 V, 7 ranges Current range: 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated) Power range: 6.0000 W to 2.2500 MW (depends on combination of voltage and current range) Frequency range: 0.5Hz to 5kHz Basic accuracy Voltage: ¡¾0.05% rdg. ¡¾0.05% f.s. Current: ¡¾0.05% rdg. ¡¾0.05% f.s. + current sensor accuracy Active power: ¡¾0.05% rdg. ¡¾0.05% f.s. + current sensor accuracy Synchronization frequency range 0.5Hz to 5kHz Frequency band DC, 0.5Hz to 150kHz Data update rate 50ms (For harmonic measurement, depends on the synchronization frequency when less than 45Hz) Display refresh rate 200ms (Independent of internal data update rate; waveform and FFT depend on the screen) Data save interval OFF, 50m/ 100m/ 200m/ 500msec, 1/ 5/ 10/ 15/ 30sec, 1/ 5/ 10/ 15/ 30/ 60minutes External interfaces LAN, USB (communication/ memory), RS-232C, CF card, Synchronization control Power supply 100 to 240V AC, 50/60Hz, 140VA max. Dimensions, mass 340mm (13.39in) W ¡¿ 170mm (6.69in) H ¡¿ 157mm (6.18in) D, 4.8kg (169.3oz) Supplied accessories Instruction Manual ¡¿ 1, Measurement Guide ¡¿ 1, Power cord ¡¿ 1, USB cable ¡¿ 1, D-sub connector ¡¿ 1 (when 9792 or 9793 is installed), Color label ¡¿ 2 Specifications for the Motor Testing Option Number of input channels 3 channels, CH A: Torque signal input (DC V / Frequency input), CH B: Rotation signal input (DC V / Pulse input), CH Z: Z-phase signal input (Pulse input) Measurement item Voltage, Torque, Rotation, Frequency, Slip, Motor power DC V (CH A/ B) Measurement range: ¡¾1 V/ ¡¾5 V/ ¡¾10 V, Accuracy: ¡¾0.1 % rdg. ¡¾0.1 % f.s. Frequency (CH A) Effective amplitude range: ¡¾5 V peak, Measurement band: 1 kHz to 100 kHz Pulse (CH B) Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 1 Hz to 200 kHz Pulse (CH Z) Detection level: (Low) 0.5 V or less, (High) 2.0 V or more,

¹è¼ÛÁö¿ª : Àü±¹

¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 3ÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
     ¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
     [¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼­)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]

¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 3ÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)