Ȩ | ·Î±×ÀÎ | ȸ¿ø°¡ÀÔ | Àå¹Ù±¸´Ï | ¹è¼ÛÁ¶È¸
     
    
¼öÁúÃøÁ¤±â/ȯ°æ/ÆÄƼŬÀåºñ
¿Â½Àµµ°èÃø±âdz¼Ó/dz¾Ð/LED»öÂ÷°è/Á¶µµ°è¿¬¼Ò°¡½º/°¢Á¾°¡½ºÃøÁ¤±â¼ÒÀ½°è/À̽½Á¡Mnno/¼Óµµ,ȸÀü,Taco meter/³Ã¸ÅÆÄƼŬī¿îÅÍ/ºÐÁø´Ù±â´ÉÃøÁ¤±â³óµµ/´çµµ/¿°µµÃÊÀ½Æĵβ²/µµ¸·µÎ²²/¼öºÐÃøÁ¤±â¼öÁúºÐ¼®±â°úÇкм®±â±âÀÌÈ­Çбâ±â¹æ»ç¼±ÃøÁ¤±âÈÖµµ°è·¹ÀÌÀú°Å¸®ÃøÁ¤±â¼¾¼­ÇüPH¸ÞÅÍÀú¿ï/±æÀÌ/Áøµ¿½ºÆ®·Îºê/³»½Ã°æÁøµ¿°è¿­·ù°èÃÊÀ½ÆÄÀ¯·®°èµðÁöÅоз°èȯ°æÀåºñ¿À¿°ºÐ¼®±â¼ÒÇüÈí¿¬ÃøÁ¤±âBIT ¿£Áö´Ï¾î¸µÃÊÀ½ÆÄŽ»ó±âÀüÀÚÆÄ/Á¤Àü±â/°¡¿ì½º¸ÞŸKAIRDATEGAMÂ÷¾Ð°è°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñÀ¯¼Ó°è°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñ°øÀåµî·ÏÀåºñÀ̵¿½ÄÀ¯·®°èÁ¤Àü±âÃøÁ¤±âK.R.KAMittari¾Æ¹ÌŸ¸® HUATECGSUNSADTTENMARSTOA¹Ì¼¼¸ÕÁöÃøÁ¤±â

¼ÒÀ½°è S4023SD
470,000¿ø

HMI41 & HMP46 Relative Humidity Meter
°¡°Ý¹®ÀÇ

HM70 Relative Humidity Meter for High Dewpoints
°¡°Ý¹®ÀÇ

DM70 Dewpoint Meter for Industrial Use
°¡°Ý¹®ÀÇ

Portable Dewpoint Meter SADPmini
°¡°Ý¹®ÀÇ

Portable Dewpoint Meter DSP-EX
°¡°Ý¹®ÀÇ

Digital Sound Level Meter TES-1350A
°¡°Ý¹®ÀÇ

FT3432 ¼ÒÀ½°è(30~130dB)
°¡°Ý¹®ÀÇ

UT 352 ¼ÒÀ½°è
°¡°Ý¹®ÀÇ

407790
°¡°Ý¹®ÀÇ

   Home > ¼öÁúÃøÁ¤±â/ȯ°æ/ÆÄƼŬÀåºñ > ¼ÒÀ½°è/À̽½Á¡ > ¼ÒÀ½°è/À̽½Á¡ÃøÁ¤±â
 
MODEL : 735   
¼ÒÀ½°è (µ¥ÀÌÅͷΰÅ,RS-232)
   
 ÆǸŰ¡°Ý
: °¡°Ý¹®ÀÇ(VATº°µµ)
 Àû¸³±Ý : 0 ¿ø
 ³³±âÀÏ : 4ÁÖÀÏÀ̳»
 ¼ÒºñÀÚ°¡
: 460,000 ¿ø
 ±¸¸Å¼ö·®
: °³
 ´ë·®±¸¸Å½Ã °ßÀûÈÄ ±¸¸ÅÇÏ½Ã±æ ¹Ù¶ø´Ï´Ù!
 Ä«µå°¡´É¿©ºÎ : Ä«µå±¸¸ÅºÒ°¡
 
 
 

ºñÆ®¸¶Æ®¸¦ ã¾ÆÁּż­ °¨»çÇÕ´Ï´Ù. ÁÁÀº ÇÏ·ç µÇ¼¼¿ä!
 
   
Á¦¸ñ ¾øÀ½

Spec ¹× Ư ¼º

  • Windows Software Included
  • Clock Display
  • 32,000 Records Data Logger
  • RS-232 Interface
  • Bargraph
  • MAX/MIN function
  • Auto Ranging (30 ~ 130dB)
  • Resolution 0.1dB
  • Level Range Display
  • AC/DC Signal Output
  • Auto Power Off
  • Backlit LCD

     
  • Specifications models 732A and 735
    Standard applied IEC 651 Type2, ANSI S1.4 Type2
    Frequency range 31.5Hz ~ 8kHz
    Measuring level range 30 ~ 130dB
    Frequency weighting A / C
    Microphone 1/2 inch electret condenser microphone
    Display LCD
    Digital display 4 digits
    Resolution: 0.1dB
    Display Update: 0.5 sec.
    Analog display 50 segment bargraph
    Resolution: 1dB
    Display Update: 50 mS
    Time weighting FAST (125mS), SLOW (1 sec.)
    Level ranges Lo: 30 – 80 dB
    Med: 50 – 100 dB
    Hi: 80 – 130 dB
    Auto: 30 – 130 dB
    Accuracy ±1.5dB (under reference conditions @ 94dB, 1kHz)
    Dynamic range 100 dB (50 dB model 732A)
    Alarm function "OVER" is when input is more than the upper limit of range.
    "UNDER" is when input is less than the lower limit of range.
    MAX/MIN hold Holds readings the Maximum and Minimum Value.
    AC output 1 Vrms at FS (full scale)
    Output impedance: approx. 100¥Ø
    FS: means the upper limit of each level range.
    DC output 10mV / dB, output impedance approx. 1k¥Ø
    Power supply One 9V battery, 006P or IEC 6F22 or NEDA 1604.
    Power life About 50hrs (alkaline battery)
    AC adapter Voltage 9 VDC, center pin negative, (8–15VDC Max)
    Supply current: > 30mADC
    Socket: pin ¡æ Ground, Casing ¡æ Positive, External Diameter ¡æ 3.5mm, Internal Diameter ¡æ 1.35mm
    Electromagnetic Compatibility RF field = 3V/m
    Total accuracy = specified accuracy + 0.5dB
    Operation temperature 0 to 40°C (32° to 104°F)
    Operation humidity 10 to 90%RH
    Storage temperature -10° to 60°C (14° to 140°F)
    Storage humidity 10 to 75%RH
    Dimensions (L × W × H) 10.8 × 2.5 × 1.2¡È (275 × 64 × 30mm)
    Weight 285g (including battery)
    Accessories 9V battery, carrying case, Screwdriver, Instruction manual. Windscreen, 3.5¥õ plug, software & RS-232 cable (optional model 732A).

     


    ¹è¼ÛÁö¿ª : Àü±¹

    ¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼­,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
    º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
         ¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
         [¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼­)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]

    ¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)