¡á | ÁÖÆļö ¹üÀ§ | 50Hz to 100 kHz | ¡á | ÀÓÇÇ´ø½º/ÀúÇ×(Z ,R) | 0.0000 Ohm to 200 MOhm | ¡á | Äܵ§¼(C) | 0.0 pF to 31.8mF | ¡á | ÀδöÅϽº(L-ÄÚÀÏ) | 0.0 uH to 637 kH | ¡á | DC Å×½ºÆ® ¸ðµå | 300 mV , 1V , 2V | ¡á | Q | 0.002 to 1000 | ¡á | D | 0.002 to 1000 | ¡á | Á¤È®µµ | 0.1% (PM6304C ´Â 0.05%) | ¡á | DC ¹ÙÀ̾(³»ºÎ) | 2 V | ¡á | DC ¹ÙÀ̾(¿ÜºÎ) | 0 to 40 V | ¡á | Bin ÇÁ·Î±×·¥ | IEEE488 , RS-232 | ¡á | ¸®¸ðÆ® Bin ÇÁ·Î±×·¥ | PM 9559B | | | |
AC Test Mode | Test frequency | PM 6306: 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps) 100 kHz to 1 MHz (1 kHz steps) PM 6304: 50, 60, 100, 120 Hz 200 Hz to 20 kHz (100 Hz steps) 100 kHz | Test frequency accuracy | PM 6306: 0.01% PM 6304: 0.01% | Test signal levels | PM 6306: 50 mV to 2V (10 mV steps) via 100W PM 6304: 50 mV via 100W 1V via 100W 2V via 400W
| Basic measurement accuracy at normal measurement mode | PM 6306: 0.1% ¡¾ 1 digit (for ©ø 0.25V, £ 50 kHz) 0.1% * (f/50 kHz) ¡¾ 1 digit (for ©ø 0.25V, > 50 kHz) 0.1% * (0.25V/Vt) ¡¾ 1 digit (for < 0.25V, £ 50 kHz) PM 6304: 0.05% ¡¾ 1 digit (for PM 6304C, £ 2 kHz) 0.1% ¡¾ 1 digit (for £ 20 kHz) 0.4% ¡¾ 1 digit (100 kHz) 0.5% ¡¾ 1 digit (for 50 mV £ 20 kHz) 2.0% ¡¾ 1 digit (for 50 mV, 100 kHz)
|
DC bias | Internal | PM 6306: 0 to 10V (0.1V steps) PM 6304: 2V | External | PM 6306: 0 to 40V PM 6304: 0 to 40V |
DC test mode (Optional) | Test signal levels | PM 6306: 50 mV to 2V (10 mV steps) via 100W PM 6304: 300 mV via 100W 1V via 100W 2V via 400W
| Basic measurement accuracy | PM 6306: 0.1% ¡¾ 1 digit (for ©ø 0.25V) PM 6304: 0.1% ¡¾ 1 digit (for 1V) |
Maximum measuring ranges | Impedance/Resistance AC Z or RAC | 0.0000W to 200 MW | Resistance DC RDC | 0.0000W to 50 MW | Capacitance C | 0.00 pF to 31.8F | Inductance L | 0.00 mH to 637 kH | Quality factor Q | 0.000 to 1000 | Dissipation factor D | 0.000 to 1000 | Phase Angle F | -179 to + 180 deg | Voltage monitor VX | 0.1 mV to 2.00V | Current monitor IX | 0.005 mA to 10.0 mA |
Maximum resolution | Impedance/Resistance AC Z or RAC | 0.1 mW | Resistance DC RDC | 0.1 mW | Capacitance C | 0.01 pF | Inductance L | 0.01 mH | Quality factor Q | 0.001 | Dissipation factor D | 0.001 | Phase angle F | 0.1 deg | Voltage monitor VX | 0.1 mV | Current monitor IX | 0.001 mA |
Auto Mode | Read-out | Dominant and secondary parameter | Equivalent circuit diagram | Parallel for R+C, Serial for R+L |
Manual mode | Read-out | Dominant and secondary parameter or Z, F, D, Q, VX, IX | Equivalent circuit diagram | Parallel or serial selectable |
Average function | Function | Exponential averaging in continuous mode | Levels | PM 6306: 3 (and off) PM 6304: 1 (and off) |
Measuring modes (Normal) | Continuous | 2 measurements/s | Single | Triggered via "TRIG" key Triggered via handler interface Triggered via IEEE-488 or RS-232
| Test frequency | PM 6306: 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps) 100 kHz to 1 MHz (1 kHz steps) DC (optional) PM 6304: 50, 60, 100, 120 Hz 200 Hz to 20 kHz (100 Hz steps) 100 kHz DC (optional)
| Read-out | Display or via IEEE-488 or RS-232 interface |
Measuring Modes (Fast) | Max. speed | 10 measurements/s | Test frequency | PM 6306: 200 Hz to 100 kHz (200 Hz steps) 100 kHz to 1 MHz (1 kHz steps) DC (optional) PM 6304: 200 Hz to 20 kHz (200 Hz steps) 100 kHz DC (optional) | Single | Triggered via handler interface Triggered via IEEE-488 or RS-232 | Read-out | Via IEEE or |
Measuring Modes (Fast) | Max. speed | 10 measurements/s | Test frequency | PM 6306: 200 Hz to 100 kHz (200 Hz steps) 100 kHz to 1 MHz (1 kHz steps) DC (optional) PM 6304: 200 Hz to 20 kHz (200 Hz steps) 100 kHz DC (optional) | Single | Triggered via handler interface Triggered via IEEE-488 or RS-232 | Read-out | Via IEEE or RS-232 interface (display blanked) |
Binning | Standard bins | 9 | Special bins | Bin "0" and bin "fail" | Bin programming via | IEEE-488 interface RS-232 interface Bin programmer (PM 6304 only) | Bin limit programming | Absolute or relative |
Trim function | Open circuit | Open circuit compensation Z > 100 kW | Short circuit | Short circuit compensation Z < 10W |
Protection against charged capacitors | C < 2 mF | PM 6306: Vmax < 200V PM 6304: Vmax < 500V | 2 mF o C o 2 mF | PM 6306: Vmax < 47 x (C/mF) -0.234 (Vmax in V, C in mF) PM 6304: Vmax. < 117 x (C/mF) -0.234 (Vmax in V, C in mF) |
Environmental Conditions | Operating temperature | 0¡Æ to 50¡Æ C | Storage temperature | -40¡Æ C to 70¡Æ C | Power requirements | 100/120/220/240V + 10% | Line frequency | 50/60 Hz | Power Consumption | PM 6306: 44 VA PM 6304: 31 VA | Safety | According to CE-regulation 73/23 EN61010-1 CAT II, Pollution Degree 2 | EMC | According to CE regulation 89/336: Emission according to EN 55011, Group 1 Class B, respectively CISPR 11. Immunity according to EN 50082-1, inclusive IEC 801-2, -3, -4 | Warm-up time | PM 6306: 30 minutes PM 6304: 5 minutes |
Dimensions and weight | W x H x D | 315 x 105 x 405 mm (12.4 in x 4.13 in x 15.9 in) | Weight | PM 6306: 5.3 kg (11.7 lb) PM 6304: 4.7 kg (10.4 lb) |
|
|
|
¹è¼ÛÁö¿ª : Àü±¹
¹è¼Ûºñ : 3,000ÀÔ´Ï´Ù.(µµ¼,»ê°£,¿ÀÁö ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
º» »óÇ°ÀÇ Æò±Õ ¹è¼ÛÀÏÀº 4ÁÖÀÏÀ̳»ÀÔ´Ï´Ù.(ÀÔ±Ý È®ÀÎ ÈÄ)
¼³Ä¡ »óÇ°ÀÇ °æ¿ì ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
[¹è¼Û¿¹Á¤ÀÏÀº ÁÖ¹®½ÃÁ¡(ÁÖ¹®¼ø¼)¿¡ µû¸¥ À¯µ¿¼ºÀÌ ¹ß»ýÇϹǷΠÆò±Õ ¹è¼ÛÀÏ°ú´Â Â÷ÀÌ°¡ ¹ß»ýÇÒ ¼ö ÀÖ½À´Ï´Ù.]
¹è¼Û±â°£ :ÁÖ¹®ÀÏ Æ÷ÇÔ 4ÁÖÀÏÀ̳»¿¡ »óÇ°À» ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù. (¿¬ÈÞ/°øÈÞÀÏ Á¦¿ÜÀ̸ç, Çö±Ý ÁÖ¹®ÀÏ °æ¿ì ÀÔ±ÝÀÏ ±âÁØÀÔ´Ï´Ù.)
|
|
|
|
|